Climate Wizard M-cycle Indirect Evaporative cooling technology uses a hyper-efficient heat exchanger to produce 100% fresh, cool, outside air, with no added moisture.
The fresh cold air produced by M-cycle indirect evaporative coolers can be similar to that produced by refrigerated systems, with temperatures that approach the ambient dew-point temperature, using up to 80% less energy.
No matter how hot it gets outside, M-cycle indirect evaporative coolers use the same amount of power and still deliver 100% fresh, cool air inside. This is in direct contrast to refrigerated systems, which require increasing amounts of power as outside temperatures rise.
M-cycle Indirect evaporative cooling is for ideal in pre-cooling application, stand-alone or supplementary cooling. They cover an exceptionally large range of flexible configurations in a wide range of industries.
Climate Wizard is a world first and the innovation revolution of the century in cooling technology, using a new way of cooling to deliver unparalleled cooling levels at a fraction of the cost of refrigerated air conditioning. This proven technology has now been successfully adopted across the world.
Climate Wizard uses a patented heat exchanger to super-cool the air below the outdoor temperature.
Let’s have a look at M-cycle indirect evaporative technology more in details:
How does it work?Explore the benefitsEnergy-Saving coolingApplications and configurationsDiscover the key features
Discover the key features
Discover the key features
Discover the key features
Discover the key features
Discover the key features
Discover the key features
M-cycle indirect evaporative air conditioners use a hyper-efficient patented heat exchanger to produce 100% fresh, cool, outside air, with no added moisture.
The core is an air-to-air heat exchanger consisting of alternating dry and wet channels.
Seeley International has designed the most advanced technology to give you full control of your coolers in the smartest way.
All Climate Wizard H-series and CW-80 coolers can be controlled with the advanced Multi Magic controller suite, including:
Climate Wizard CW3 can be controlled with the MagIQtouch suite of controllers, which includes:
Improved IAQ (Indoor Air Quality) with 100% fresh, cool outside air never recirculating stale and recycled air. Temperatures are similar to those produced by refrigerated systems, not adding any moisture to the air.
No high electrical demand charges even in hot weather. Reduce the energy use and improve the cooling performance of existing refrigerated systems (when installed in pre-cooling or supplementary cooling). Total cooling performance increases when air temperature rises.
Covers an exceptionally large range of flexible configurations (pre-cooling, stand-alone or supplemetary cooling) in a wide range of applications, from light commercial to big industrial plants.
No synthetic refrigerants are used to cool the air, only water used. Climate Wizard used an exclusive WaterManagement system that helps minimising water consumption.
Climate Wizard’s cooling performance can rival that of refrigerated systems, using up to 80% less energy.
That’s not only great for reducing power bills; it’s also great for the environment. And, no matter how hot it gets outside, Climate Wizard uses the same amount of power and still delivers 100% fresh, cool air inside.
This is in direct contrast to refrigerated systems, which require increasing amounts of power as outside temperatures rise. Climate Wizard’s cost-saving capabilities actually increase, when the heat is at its highest.
At the same time, Climate Wizard’s performance also increases as temperatures rise – again, in complete contrast to refrigerated systems.
Evaporative cooling uses water to cool. This helps reduce the production of greenhouse gases, including harmful hydroflourocarbons. We have estimated that in a location like Madrid (Spain) using Climate Wizard you can reduce running costs up to 82%1 and carbon emissions up to 89%2.
The technologically advanced water management system continuously checks the quality of the water in your cooler. The system automatically replaces the water when mineral deposits exceed an acceptable level. The optimal result: minimum water use for maximum, fresh cooling power. Furthermore, you can generate your own cooling medium by rain water harvesting and to create a water neutral solution, you can use the waste water for grey, fire or irrigation.
Supported by a team of experienced design consultants and engineers, Climate Wizard M-cycle Indirect Evaporative Cooling covers an exceptionally large range of
flexible configurations in a wide range of industries.
The Climate Wizard can be installed in stand alone configuration, when fresh air is needed directly into the space and no other cooling system is previously installed. This way, we directly take advantage of Indoor Air Quality improvement for staff & customers.
M-cycle Indirect evaporative cooling can be retro-fitted to existing reverse cycle VRF installations to pre-cool outside air in any workspace or commercial application, providing fresh cool air to reduce the cooling load on an air handling unit already installed. Acting like an ‘efficiency turbo charger’ the savings are immediate.
The key is to hyper-efficiently pre-cool air before it enters the refrigerated air conditioning system. Compressors don’t need to struggle in extreme summer conditions when fed with pre‑cooled air from The Climate Wizard. This significantly reduces the load on the system’s energy-hungry compressors.
You can significantly reduce the load on compressors & extends the compressor’s life, even when installation makes it diffucult to install The Climate Wizard in pre-cooling (or when unit’s physical layout does not allow direct connection with our indirect evaporative cooler).
The Climate Wizard can be installed in a convenient location, in parallel with a chiller for example. The Climate Wizard provides fresh outside air, while the chiller continues cooling the air inside the building, actually pre-cooled by The Climate Wizard.
[1] Seeley International’s running costs comparison is a calculation based on assumptions including Building dimensions 1000m2floor area x 6m high; Cooling time 12hrs/day, 6 summer months/year; Indoor temperature 22°C; Building heat load 100W/m²; Rooftop Unit -Fresh air 1,170 l/sec (20%); Rooftop Unit -COP 3; External ambient conditions based on Typical Meteorological Years (TMY) for Madrid (Spain); Power cost 0.11 €/kWh; Water cost 1.5 €/m³;Electricity Generation CO2equivalent 340gCO2eq/kWh. The comparison should be used as a general guide only.
[2] Seeley International’s running costs comparison is a calculation based on assumptions including Building dimensions 1000m2floor area x 6m high; Cooling time 12hrs/day, 6 summer months/year; Indoor temperature 22°C; Building heat load 100W/m²; Rooftop Unit -Fresh air 1,170 l/sec (20%); Rooftop Unit -COP 3; External ambient conditions based on Typical Meteorological Years (TMY) for Madrid (Spain); Power cost 0.11 €/kWh; Water cost 1.5 €/m³;Electricity Generation CO2equivalent 340gCO2eq/kWh. The comparison should be used as a general guide only.